{thermokon/duct_sensors/climate_air_quality/lk_plus.prj},{NB=662345 LK+ CO2 Temp RS485 Modbus (300)},{ARTNR=662345},{EL=180},{IDPIM3=5135},{BEZ=LK+ CO2 Temp RS485 Modbus},{GGEO=},{GEOV=},{REF3D=LK+ USE M},{BILD=lk_plus.png},{INFOWWW=link zur Website},{MESSG= Temperatur, CO2},{AT= Kanalfühler},{BF=0},{BE=0},{KONFIG= Thermokon App, uConfig, BUS, Jumper, DIP-Schalter},{S= NDIR (nicht dispersiv, infrarot)},{AGSPA= 2x 0..10 V oder 0..5 V, einstellbar über Jumper, live-zero-Konfiguration über App oder uConfig, min. Last 10 kΩ},{AGST=---},{AGSK=---},{EG=0},{NTECH= RS485 Modbus},{FTECH=0},{DUT=RS485 Modbus RTU, halbduplex, Baudrate 9.600, 19.200, 38.400 oder 57.600, Parität: keine (2 Stoppbits), gerade oder ungerade (1 Stoppbit)},{LOD=300}
請根據技術需求選擇所需產品. 可選屬性在表格中高亮顯示. 選擇可以通過點擊表格或數值來重置.
HELP_VARIABLE
Naming
LK+ CO2 Temp RS485 Modbus
LK+ CO2 Temp RS485 Modbus
Article Number
662345
662345
Level of Detail
300
200
300
200
Picture
link to website
link to website
Measured values
temperature, CO2
temperature, CO2
Application/type
Duct sensor
Configuration
Thermokon app, uConfig, BUS, jumper, DIP switches
Thermokon app, uConfig, BUS, jumper, DIP switches
Sensor
NDIR (non-dispersive, infrared)
NDIR (non-dispersive, infrared)
Output voltage
2x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ
2x 0..10 V or 0..5 V, adjustable via jumper, live-zero configuration via app or uConfig, min. load 10 kΩ
Output current
---
---
Output switching contact
---
---
Network technology
RS485 Modbus
RS485 Modbus
Data transmission
RTU, half-duplex, baud rate 9.600, 19.200, 38.400 or 57.600, parity: none (2 stop bits), even or odd (1 stop bit)
RTU, half-duplex, baud rate 9.600, 19.200, 38.400 or 57.600, parity: none (2 stop bits), even or odd (1 stop bit)
Operating range temperature
0 - +50
Accuracy temperature
±0,5 K (typ. at 21 °C), within default measuring range, offset setting via app or uConfig
±0,5 K (typ. at 21 °C), within default measuring range, offset setting via app or uConfig
Output signal temperature
scaling analogue output, 0..+50 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C, optionally configurable
scaling analogue output, 0..+50 °C (default setting), selectable from 4 temperature ranges -40..+60 | 0..+50 | -20..+80 | -15..+35 °C, optionally configurable
Operating range humidity
max. 85% rH short term condensation
Measuring range humidity
---
---
Accuracy humidity
---
---
Measuring range CO2
0..2000, 0..5000, optionally configurable
0..2000, 0..5000, optionally configurable
Accuracy CO2
±50 ppm +3% of measured value (typ. at 21 °C, 50% rH, 1015 hPa), self-calibration Dual Channel
±50 ppm +3% of measured value (typ. at 21 °C, 50% rH, 1015 hPa), self-calibration Dual Channel
Measuring VOC mixed gas
---
---
Power supply
15..35 V = SELV, 19..29 V ~ SELV
15..35 V = SELV, 19..29 V ~ SELV
Power consumption
max. 2,5 W (24 V =), 4,3 VA (24 V ~)
Material in touch with media
Pipe, Ø=19,5 mm, black, length 180 mm
Pipe, Ø=19,5 mm, black, length 180 mm
Installation length
180
180
mm
Display
---
---
Enclosure
USE-M, impact- and shock-resistant enclosure with quick-release cover, PC
Colour
pure white
pure white
Protection IP
IP65, according to EN 60529
Connection
removable cable entry M25 with fourfold cable entry for wire with max. Ø=7 mm, removable plug-in terminal, max. 2,5 mm², BUS max. 1,5 mm²
removable cable entry M25 with fourfold cable entry for wire with max. Ø=7 mm, removable plug-in terminal, max. 2,5 mm², BUS max. 1,5 mm²
Packaging
87 x 87 x 250
87 x 87 x 250
Delivery content
incl. mounting flange, incl. mounting set (screws and accessories)